Kerkhof & Lindner

Timber & Masonry Building Physics

Independent structural diagnostics for pre-1945 timber framing, load-bearing brickwork, and foundation moisture balance. We carry out non-destructive on-site measurements for architects, municipal heritage officers, and structural engineers prior to renovation or change of use.

Diagnostic Methods & Scope

Inspection Type Method / Reference Turnaround
Timber decay & section loss Micro-drilling resistance (3.0 mm needle), ultrasonic pulse velocity 4–6 working days
Moisture & salt profiling Gravimetric core sampling, calcium carbide (CM) & microwave mapping 3–5 working days
Masonry & mortar bond Endoscopic cavity inspection, flat-jack stress check (ASTM C1196) 5–8 working days
Residual load assessment Grade verification & cross-section calculation per EN 1995-1-1 5–7 working days

Selected Field Notes

REF 2026-104 · UTRECHT · OAK ROOF TRUSSES
Hidden fungal decay at wall-plate bearings in a 1912 warehouse
Visual surface checks indicated dry timber (13% RH), while resistance drilling at 45° into the embedded beam ends revealed a 65 mm internal pocket of brown rot behind unventilated exterior brickwork.
REF 2026-089 · ROTTERDAM · BRICK VAULTING
Hygroscopic chloride accumulation above ground-floor damp-proof course
Core samples taken at 300 mm intervals confirmed that seasonal condensation, rather than capillary groundwater rise, accounted for plaster delamination along the north party wall.

Office & Field Scheduling

Correspondence
desk@kerkhof-diagnostics.nl
Reports issued in English, Dutch, or German.
Laboratory & Dispatch
Oosterkade Workshop Wing, Utrecht
Mon–Fri, 08:30–17:00 CET (site visits by appointment)